Inlet pressure :P1=0.4-0.8Mpa
Outlet pressure:P2=3-15 Kpa
Flow rate:Q=500 Nm³/h
Interface size:DN50 / DN100
Function: gasification, filter, pressure regulating and metering, add smelly, etc
Inlet pressure :P1=0.4-0.8Mpa
Outlet pressure:P2=3-15 Kpa
Flow rate:Q=500 Nm³/h
Interface size:DN50 / DN100
Function: gasification, filter, pressure regulating and metering, add smelly, etc
Inlet pressure :P1=0.4-0.8Mpa
Outlet pressure:P2=3-15 Kpa
Flow rate:Q=500 Nm³/h
Interface size:DN50 / DN100
Function: gasification, filter, pressure regulating and metering, add smelly, etc
Inlet pressure :P1=0.4-0.8Mpa
Outlet pressure:P2=5-15 Kpa
Flow rate:Q=1000 Nm³/h
Interface size:DN50 / DN150
Function: gasification, filter, pressure regulating and metering, add smelly, etc
Inlet pressure :P1=0.4-0.8Mpa
Outlet pressure:P2=3-7 Kpa
Flow rate:Q=200 Nm³/h
Interface size:DN25 / DN80
Function: gasification, electric heating filter, pressure regulating and metering, add smelly, etc
Inlet pressure :P1=0.4-0.8Mpa
Outlet pressure:P2=3-7 Kpa
Flow rate:Q=200 Nm³/h
Interface size:DN25 / DN80
Function: gasification, electric heating filter, pressure regulating and metering, add smelly, etc
Inlet pressure :P1=0.4-0.8Mpa
Outlet pressure:P2=3-7 Kpa
Flow rate:Q=300 Nm³/h
Interface size:DN25 / DN80
Function: gasification, filter, pressure regulating and metering, add smelly, etc
Inlet pressure :P1=0.4-0.8Mpa
Outlet pressure:P2=5-15 Kpa
Flow rate:Q=1000 Nm³/h
Interface size:DN50 / DN150
Function: gasification, filter, pressure regulating and metering, add smelly, etc
Inlet pressure :P1=0.4-0.8Mpa
Outlet pressure:P2=3-7 Kpa
Flow rate:Q=800 Nm³/h
Interface size:DN40 / DN100
Function: gasification, electric heating filter, pressure regulating and metering, add smelly, etc
Inlet pressure :P1=0.4-0.8Mpa
Outlet pressure:P2=3-7 Kpa
Flow rate:Q=800 Nm³/h
Interface size:DN40 / DN100
Function: gasification, electric heating filter, pressure regulating and metering, add smelly, etc
Inlet pressure :P1=0.6-1.0 Mpa
Outlet pressure:P2=0.4 Mpa
Flow rate:Q=6000 Nm³/h
Interface size:DN80 / DN200
Function: gasification, electric heating filter, pressure regulating and metering, add smelly, etc
Inlet pressure :P1=0.6-1.0 Mpa
Outlet pressure:P2=0.4 Mpa
Flow rate:Q=6000 Nm³/h
Interface size:DN80 / DN200
Function: gasification, electric heating filter, pressure regulating and metering, add smelly, etc
Inlet pressure :P1=0.6-1.0 Mpa
Outlet pressure:P2=0.29 Mpa
Flow rate:Q=12000 Nm³/h
Interface size:DN150 / DN300
Function: gasification, Hot water heating ,filter, pressure regulating and metering, etc
Inlet pressure :P1=0.6-1.0 Mpa
Outlet pressure:P2=0.29 Mpa
Flow rate:Q=12000 Nm³/h
Interface size:DN100 / DN200
Function: gasification, Hot water heating ,filter, pressure regulating and metering, etc
Inlet pressure :P1=0.6-1.0 Mpa
Outlet pressure:P2=0.4 Mpa
Flow rate:Q=8000 Nm³/h
Interface size:DN100 / DN250
Function: gasification, filter, pressure regulating and metering, add smelly, etc
Inlet pressure :P1=0.4-0.8 Mpa
Outlet pressure:P2=3-7 Kpa
Flow rate:Q=50 Nm³/h
Interface size:DN20/ DN40
Function: gasification, filter, pressure regulating etc ( LNG gasification station storage tank )
Volume :5m3-700m3
Working pressure:0.5MPa ~ 1.6Mpa
Type:vertical and horizontal
Interface size:none
none
Function: vacuum powder insulation, high vacuum multilayer winding insulation and other insulation materials
Volume :5m3-400m3
Working pressure:0.2MPa ~ 3.5Mpa
Media:LOX, Lin, LAR, LNG, lco2, lc2h4
Design standards:GB, en, ASME
Insulation methods: vacuum powder insulation, high vacuum multilayer winding insulation and other insulation materials
Volume :5m3-400m3
Working pressure:0.2MPa ~ 3.5Mpa
Media:LOX, Lin, LAR, LNG, lco2, lc2h4
Design standards:GB, en, ASME
Insulation methods: vacuum powder insulation, high vacuum multilayer winding insulation and other insulation materials
Volume :18.2m3-45.5m3
Working pressure:0.6MPa ~ 1.8Mpa
Specification :20 feet, 40 feet
Features : through CCS, BV and other certification, users can obtain the certification of other international classification societies according to their needs to meet the requirements of international shipping.
Volume :18.2m3-45.5m3
Working pressure:0.6MPa ~ 1.8Mpa
Specification :20 feet, 40 feet
Features : through CCS, BV and other certification, users can obtain the certification of other international classification societies according to their needs to meet the requirements of international shipping.
Volume :18.2m3-45.5m3
Working pressure:0.6MPa ~ 1.8Mpa
Specification :20 feet, 40 feet
Features : through CCS, BV and other certification, users can obtain the certification of other international classification societies according to their needs to meet the requirements of international shipping.
Volume :10.62m3-37.4m3
Working pressure:0.3MPa ~ 1.6Mpa
method :High vacuum insulation winding method
Medium : liquid oxygen, liquid nitrogen, liquid argon, liquid ethylene Features: with pump and without pump series, complete vehicle, single axle, two axle and three axle semi-trailer. Light weight, large volume and low operation cost.
Volume :20m3
Working pressure:1.64MPa ~ 2.2Mpa
Specification :20 feet, non-standard
Features : through CCS and bv certification, users can obtain the certification of other international classification societies according to their needs to meet the requirements of international shipping.
Volume :5m3
Working pressure:2.2Mpa
Type : vertical and horizontal
Features : through CCS and bv certification, users can obtain the certification of
Volume :200m3-10000m3
Working pressure:10kpa-50kpa
Media : LOX, Lin, LAR, LNG, lc2h4, etc
Insulation method : double wall powder accumulation insulation
According to different supply objects, LNG gasification station can be divided into single point direct gas supply station and LNG satellite station, which are used to receive, store and gasify the LNG purchased upstream to supply gas to the local area. LNG gasification stations can be regarded as small LNG receiving stations, and some gasification stations are also equipped with liquefaction devices.