Inlet pressure :P1=4.0-5.5Mpa
Outlet pressure:P2=0.4-0.6 Mpa
Flow rate:Q=120000 Nm³/h
Interface size:DN250 / DN600
Features:filter, metering, heat transfer, pressure regulating---City gas gate station
Inlet pressure :P1=4.0-5.5Mpa
Outlet pressure:P2=0.4-0.6 Mpa
Flow rate:Q=120000 Nm³/h
Interface size:DN250 / DN600
Features:filter, metering, heat transfer, pressure regulating---City gas gate station
Inlet pressure :P1=4.0-5.5Mpa
Outlet pressure:P2=0.4-0.6 Mpa
Flow rate:Q=120000 Nm³/h
Interface size:DN250 / DN600
Features:filter, metering, heat transfer, pressure regulating---City gas gate station
Inlet pressure :P1=0.5-0.6Mpa
Outlet pressure:P2=0.2-0.3 Mpa
Flow rate:Q=10000 Nm³/h
Interface size:DN150 / DN300
Features:filter, metering, pressure regulating ----Used for steel mills
Inlet pressure :P1=0.5-0.6Mpa
Outlet pressure:P2=0.2-0.3 Mpa
Flow rate:Q=10000 Nm³/h
Interface size:DN150 / DN300
Features:filter, metering, pressure regulating ----Used for steel mills
Inlet pressure :P1=0.5-0.6Mpa
Outlet pressure:P2=0.2-0.3 Mpa
Flow rate:Q=10000 Nm³/h
Interface size:DN150 / DN300
Features:filter, metering, pressure regulating ----Used for steel mills
Inlet pressure :P1= 3.9-4.5Mpa
Outlet pressure:P2=1.6 Mpa
Flow rate:Q=150000 Nm³/h
Interface size:DN1000 / DN500X3
Features:filter, metering, pressure regulating ----Used for gas pipe network points stand
Inlet pressure :P1= 3.9-4.5Mpa
Outlet pressure:P2=1.6 Mpa
Flow rate:Q=150000 Nm³/h
Interface size:DN1000 / DN500X3
Features:filter, metering, pressure regulating ----Used for gas pipe network points stand
Inlet pressure :P1= 3.9-4.5Mpa
Outlet pressure:P2=1.6 Mpa
Flow rate:Q=150000 Nm³/h
Interface size:DN1000 / DN500X3
Features:filter, metering, pressure regulating ----Used for gas pipe network points stand
Inlet pressure :P1=0.3-0.4Mpa
Outlet pressure:P2=0.098-0.11 Mpa
Flow rate:Q=8000 Nm³/h
Interface size:DN250 / DN300
Features:filter, metering, pressure regulating ----Used in ceramic kiln
Inlet pressure :P1=0.3-0.4Mpa
Outlet pressure:P2=0.098-0.11 Mpa
Flow rate:Q=8000 Nm³/h
Interface size:DN250 / DN300
Features:filter, metering, pressure regulating ----Used in ceramic kiln
Inlet pressure :P1=0.4-0.6Mpa
Outlet pressure:P2=15-20 Kpa
Flow rate:Q=3000 Nm³/h
Interface size:DN100 / DN150
Features:filter, metering, pressure regulating ----Plants used in Algeria
Inlet pressure :P1= 0.4-0.5Mpa
Outlet pressure:P2=10-15 Kpa
Flow rate:Q=5000 Nm³/h
Interface size:DN100 / DN200
Features:filter, metering, heat transfer, pressure regulating ----For distributed energy power plant
Inlet pressure :P1= 0.4-0.5Mpa
Outlet pressure:P2=10-15 Kpa
Flow rate:Q=5000 Nm³/h
Interface size:DN100 / DN200
Features:filter, metering, heat transfer, pressure regulating ----For distributed energy power plant
Inlet pressure :P1= 2.9-3.5Mpa
Outlet pressure:P2=0.5 Mpa
Flow rate:Q=12000 Nm³/h
Interface size:DN150 / DN250
Features:filter, metering, heat transfer, pressure regulating ----For distributed energy power plant
Inlet pressure :P1= 0.2-0.3Mpa
Outlet pressure:P2=0.05 Mpa
Flow rate:Q=16000 Nm³/h
Interface size:DN200 / DN300
Features:filter, metering, pressure regulating ----Used in thermal power plant
Inlet pressure :P1= 0.2-0.3Mpa
Outlet pressure:P2=0.05 Mpa
Flow rate:Q=16000 Nm³/h
Interface size:DN200 / DN300
Features:filter, metering, pressure regulating ----Used in thermal power plant
Inlet pressure :P1= 0.2-0.3Mpa
Outlet pressure:P2=0.05 Mpa
Flow rate:Q=16000 Nm³/h
Interface size:DN200 / DN300
Features:filter, metering, pressure regulating ----Used in thermal power plant
Inlet pressure :P1= 3.6-4.0Mpa
Outlet pressure:P2=0.5-0.6 Mpa
Flow rate:Q=60000 Nm³/h
Interface size:DN200 / DN300
Features:filter, metering, heat transfe pressure regulating ----Used for LNG liquefaction plant
Inlet pressure :P1= 3.6-4.0Mpa
Outlet pressure:P2=0.5-0.6 Mpa
Flow rate:Q=60000 Nm³/h
Interface size:DN200 / DN300
Features:filter, metering, heat transfe pressure regulating ----Used for LNG liquefaction plant
Inlet pressure :P1= 3.6-4.0Mpa
Outlet pressure:P2=0.5-0.6 Mpa
Flow rate:Q=60000 Nm³/h
Interface size:DN200 / DN300
Features:filter, metering, heat transfe pressure regulating ----Used for LNG liquefaction plant
Inlet pressure :P1= 4.0-5.5Mpa
Outlet pressure:P2=1.45 Mpa
Flow rate:Q=32500 Nm³/h
Interface size:DN200 / DN400
Features:filter, metering, heat transfe pressure regulating ----City gas gate station
Inlet pressure :P1= 4.0-5.5Mpa
Outlet pressure:P2=1.45 Mpa
Flow rate:Q=32500 Nm³/h
Interface size:DN200 / DN400
Features:filter, metering, heat transfe pressure regulating ----City gas gate station
Inlet pressure :P1= 4.0-5.5Mpa
Outlet pressure:P2=1.45 Mpa
Flow rate:Q=32500 Nm³/h
Interface size:DN200 / DN400
Features:filter, metering, heat transfe pressure regulating ----City gas gate station
Inlet pressure :P1= 4.0-5.5Mpa
Outlet pressure:P2=4.0-5.5 Mpa
Flow rate:Q=42000 Nm³/h
Interface size:DN200 / DN250
Features:filter, metering, ----City gas gate station
Inlet pressure :P1= 4.0-5.5Mpa
Outlet pressure:P2=4.0-5.5 Mpa
Flow rate:Q=42000 Nm³/h
Interface size:DN200 / DN250
Features:filter, metering, ----City gas gate station
Gas pressure regulating box is an important part of gas transmission and distribution system. The box is basically equipped with inlet and outlet valves, filters, pressure regulators and corresponding measuring instruments. It can also be equipped with corrugated compensator, overpressure relief valve, overpressure shut-off valve and other auxiliary safety equipment.